The HYDAC HFM Series high-pressure inline filter provides dependable filtration for demanding hydraulic systems. Rated up to 5,800 psi with flow rates up to 37 gpm, it features a quick-response bypass valve, multiple filtration ratings and a variety of clogging indicators for reliable system protection.

Product Description

In-Line High Pressure Filter (HFM Series 5800 PSI)

The HYDAC HFM Series high-pressure inline filter provides dependable filtration for demanding hydraulic systems. Rated up to 5,800 psi with flow rates up to 37 gpm, it features a quick-response bypass valve, multiple filtration ratings and a variety of clogging indicators for reliable system protection.

Features:

• The HFM filter is available in two sizes comprised of two different bowl and element lengths. The models 75 and 95 provide
maximum flow rates of 29 and 37 GPM respectively.
• A quick-response by-pass valve located in the filter head, protects against high differential pressures caused by cold startups,
flow surges and pressure spikes.
• The high bypass pressure setting (100 psid) minimizes the possibility of contamination due to premature bypassing.
• Filter materials are compatible with all mineral, lubricating oils, and commonly used fire retardant fluids per ISO 2943.
• Fatigue pressure rating equals maximum allowable working pressure rating.
• Wide variety of indicators available with standard setting of 72 psid (5 bar).

Specifications:

Mounting Method: 3 or 4 mounting holes – filter head

Port Connection:     SAE 16, 1” BSPP

Flow Direction:   Inlet: Side    Outlet: Side.  (opposite each other)

Construction Materials:
Head                  Ductile iron
Bowl                   Steel

Flow Capacity:
75          29 gpm (110 lpm)
95         37 gpm (140 lpm)

Housing Pressure Rating:
Max. Allowable Working
Pressure                     5800 psi (400 bar)
Fatigue Pressure        Contact HYDAC office
Burst Pressure           13,920 psi (960 bar)

Element Collapse Pressure Rating:
SN                         290 psid (20 bar

Fluid Temperature Range: 14°F to 212°F (-10°C to 100°C)
Consult HYDAC for applications operating below 14ºF (-10ºC)

Fluid Compatibility:
Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the
appropriate seals are selected.

Indicator Trip Pressure:
ΔP = 72 psid (5 bar) -10% (standard)

Bypass Valve Cracking Pressure:
ΔP = 101.5 psid (7 bar) +10% (standard)

Applications:

  • Agricultural
  • Automotive
  • Construction
  • Gearboxes
  • Industrial
  • Commercial Municipal
  • Power Generation

Downloads:

In-Line Series HFM Technical Data Sheet

 

Quick Quote Title Image